Compressor: oil-free two-stage compressor

Liquefaction method: high pressure liquefaction

Vaporization method: electric heating

Annual leakage rate: ≤0.5%

Equipment size: 2700mm*1300mm*1880mm (length * width * height)

产品详情/ Product details

The SF6 High Speed Recovery unit (Winfoss-R1Tou) is a moderate capacity, full function, compact structure, SF6 compressor is completely oil-free, greatly reducing the cost of processing and filtration, the application of this technology to meet the high voltage electrical switch manufacturing enterprises and the power industry on the production process of high safety requirements. The whole device includes: oil-free SF6 compressor, vacuum compressor, vacuum pump, digital vacuum meter, electromagnetic vacuum device, low temperature condensing device, regenerative filter dryer, high pressure solenoid valve, instrumentation, safety controller, etc. The main components are imported.


SF6Gas recovery unit(WINFOSS-R1Tou)

summarize

SF6Gas recovery unitWinfoss-R1TouIt is a large capacity, full function, designed by Weavers Company for China's power industry and switch manufacturing enterprises.SF6Inflatable recycling car. Able to complete for a variety ofSF6Switch station (including column switch,GISCombined electrical appliances, switchgear, etcSF6Dielectric electrical equipment) including gas charging, recovery, vacuum, gas transfer and other full functions, including gas drying and filtration purification. The entire recovery unit includes: high-speed compressor, double-stage direct high-speed vacuum pump, electromagnetic vacuum device, drive device, American molecular regeneration filter dryer and electrical control components. Be used forSF6Gas application vacuum, inflation, recovery three functions. The equipment adopts self-developed oil-free gas compressor pairSF6Compress and store in liquid state. The system adopts double control system, fully closed structure, higher protection level.

 

SF6Gas recovery unitWinfoss-R1TouAll gas pipelines are connected with copper pipes, which has a more stable and reliable service life, and ensures reliable connection between pipelines and joints and excellent sealing performance.

adopt10.4Inch color touch screen operation, with Chinese and English interchangeable operation panel, the operation process is simple and clear, the functions and operation tips of the device are implemented on the touch screen operation, and important parameters such as pressure,SF6Gas weight, vacuum, etc. are also displayed on the touch screen, and the touch operation screen has Ethernet andUSBFunction This interface is used.

 1729501120.jpg

Functional characteristics

l   Complete functions (recycling, vacuuming, filtration and drying, storage, gas recharge) five functions.

l   Vacuum the gas storage tank and pipeline system of the device and measure the vacuum degree.

l   Vacuum extraction and vacuum measurement of sulfur hexafluoride electrical equipment.

l   Gas is recovered from sulfur hexafluoride electrical equipment and stored or pressed into cylinders, and residual pressure measurements can be made.

l   The vacuum pump has built-in anti-return valve to prevent oil return from the import and export of the recovery device.

l   The highly toxic low fluoride compounds are filtered out to bring the gas up to standard.

l   Completely filter dust and other solid impurities.

l   Gas recovery99.9%Above.

l   Recovery and recharge using two separate systems, no gas cross-contamination.

l   The interface is simple and clear, and the operation is simple.

l   Multiple safety valve Settings, eliminate safety hazards.

l   Import of core parts.

l   Regenerative filter without regular replacement.

l   Regenerative filter without regular replacement.

 

Function introduction

l  recycle: By starting the high-speed vacuum pump and electromagnetic vacuum device and other electrical control components, the equipment insideSF6The gas is extracted.

l   decontamination: Built-in full purification system, will be recycledSF6The gas is purified by repeated drying, filtration and separation.

l   Vacuum extraction:rightSF6The residual gas in the body of the switch is extracted reliably, stably and quickly through the electromagnetic vacuum device and the driving deviceSF6The switch body meets the high vacuum state required by the standard.

l   aeration: By starting the compressor in the device and the drive device, etc., to supplement a certain amount of electrical equipmentSF6The gas and inflation capacity are set according to the equipment regulations.

l   Transfer: The equipment can store the gas in the gas storage tank for a long time, and can also be used according to practical applicationsSF6Gas is transferred to the cylinder.

 

Technical parameter

 

Model number 

Winfoss-R1Tou

type 

High pressure liquefaction,Trolley type 

Operating ambient temperature 

-20° C ~45℃ 

 

SF6Oil-free two-stage compressor

Standard displacement:≥18M3/h(Max60M3/h)

Maximum suction pressure: 8bar

Exhaust pressure:50bar(50Kg/h)

 

Recovery pump

Standard displacement:30 Nm3/h

Ultimate pressure:1mbarAbsolute pressure

 

 

Vacuum pump

Standard pumping speed: 63M3/h

Ultimate vacuum:0.1 mbarAbsolute pressure(System limit vacuum0.2 mbar)

Vacuum pumping speed:≤0.5(h/M)(Vacuum from0.1 MPato133PaTake time)

Final vacuum limit: ≤10Pa. ≤0.5

Vacuum hold: in133 PaPressure maintenance24h, the vacuum value rises<400 Pa.

Initial pressure

&le;0.8MPa(20° C)

Limit value of final pressure after recovery

&le;0.5 mbar(20° C)

Gas humidity control

The<80µ L/L(SF6Gas humidity is1000µ L/LHour)

 

 

Recovery rate

1m&sup3; theSF6gas0.8 MPa,20° C) recycled to1m&sup3; Initial pressure is2MPaThe standard gas storage tank when the equipment residual pressure is reached5&times;10-3 MPaWhen, gas recovery time &le;0.7 h.; When the residual pressure of the device reaches1.33&times;10-3 MPaWhen, gas recovery time &le;0.8 h.(complete5meterDN20Pipeline)

 

Inflation rate

Output pressure133Pathe1 m&sup3; Container fillingSF6Gas arrival0.8 MPa(20℃) pressure, inflation time &le;0.2 h.(complete5meterDN20Pipeline)

Annual air leakage rate

Recovery device body<0.1%; Gas tank body <0.5%

Recycle, purify and dry

The<40µ L/L

Oil content control

0 µ g/g

Dust filtration control

Particle size<1µ m

Liquefaction mode

High pressure liquefaction

Vaporization mode

Electric heating

Dry filtration system

Vacuum heating activation regeneration

Annual leakage rate

&le;0.5%

Power source

Three-phase four-wire system,380V,50Hz   3phase220V,60Hzselectable

noisedB(A)

&le;75

Operation mode (touch control system)

adopt10.4 #Touch screen

storage

liquid

tank

Container class

Of the same category

Design pressure (MPa)

&ge;5.0(20° C)

Design temperature (℃)

40

Storage container volume (L)

300L

Storage tank capacitykg)

300kg

specification

Equipment size (length*wide*High)

2700mm*1300mm*1880mm

Equipment quality

1650kg

 

 

Standard configuration

l   SF6Gas recovery unit                      1Taiwan

l   DN20  DN40, 5Meter lengthDN20Rubber hose        1The root

l   3Meter lengthDN8Rubber bottle filling tube                   1The root

l   Adapter for recovery device and switchgear         1only

l   Cylinder connector                           1only

l   Chinese instruction manual                           1this

l   Factory inspection report and other user information               1Set of

 1729501142.png

Service guarantee

l   Provide on-site training guidance and carry out on-site demonstration operation.

l   Provide detailed instructions and user guidance in Chinese.

l   One year free warranty, lifelong spare parts support and maintenance.

l   Hot line365Answer the user's consultation day and night.


最近浏览 / Recently Viewed
相关产品 / Related Products